300/500V Single Core Thin Wall Fire Resistant Traction Cables
Applications :
- Single Core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts.
Standards :
- BS 6853 -1a
- DIN 5510-1 1-4
- NFF 16-101 F0
Construction :
- Conductors : Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
- Flame Barrier : Mica tape.
- Insulation : Electron beam crosslinkable thin wall LSZH compound.
Electrical Characteristics at 20 °C :
-
Nominal Conductor Cross Section mm² 0.5 0.75 1.0 1.5 2.5 Maximum DC Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 Voltage Rating KV 0.45/0.75
Mechanical and Thermal Properties :
- Minimum Bending Radius : 3×OD (OD<12mm); 4×OD (OD>12mm).
- Temperature Range : -40°C to +120°C.
Dimensions and Weight :
Cable Code | No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
FRA-TW-0.5SU-FR-1C0.5S | 1×0.5 | 16/0.20 | 0.30 | 2.0 | 8 |
FRA-TW-0.5SU-FR-1C0.75S | 1×0.75 | 24/0.20 | 0.30 | 2.25 | 11 |
FRA-TW-0.5SU-FR-1C1S | 1×1.0 | 32/0.2 | 0.35 | 2.50 | 14 |
FRA-TW-0.5SU-FR-1C1.5S | 1×1.5* | 30/0.25 | 0.35 | 2.8 | 19 |
FRA-TW-0.5SU-FR-1C2.5S | 1×2.5* | 50/0.25 | 0.35 | 3.2 | 29 |
Impact Resistant |
Highly Flexible |
UV Resistant |
Oil Resistant |
Weather Resistant |
Low Toxicity |
Flame Retardant NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1 |
Fire Retardant NF C32-070-2.2(C1) IEC 60332-3/EN50266 |
Zero Halogen IEC 60754-1/NF C20-454 EN 50267-2-1 |
Low Smoke Emission IEC 61034/NFC20-902 EN 50268/NF C32-073 |
Low Corrosivity EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453 |